HOWDEN LAMONA CALAGGIO TAP SPARES
Compatible spare parts to fit the Howdens Lamona Calaggio Kitchen mixer tap models
TAP3631 TAP3632 TAP3633 TAP3650 TAP8309 TAP8310.
For guidance / instructions of how to replace a tap valve step by step please
click here
If your Lamona Calaggio tap is dripping or leaking out of the spout then it is time to replace / change the quarter turn ceramic disc cartridges.
Original spare part codes known by 3794R, hot and cold valves available.
Cartridge has 28 teeth on spline.
You will require our Anti-Clockwise open cartridge for the cold side, and Clockwise. If you require both then you can select "Pair".
If you need new lever handles / tap heads you can order these which is our part SH0ASC-S
If your tap is leaking from the neck (where the spout joins the tap body) then the seals inside the spout need replacing.
When you replace the new rubber seals they need greasing with a silicone grease.
The original O'ring kit is known by 1239R.
How to remove your cartridge
Our Cartridge Valve removal tool (ST03) is available to enable easy removal and fitting of the cartridges which are recessed into the tap body.
The old valve may have two flats instead of a hex nut. Our tool has two ends.
One end to remove the cartridge with two flats and one end to remove/fit new cartridge with hex nut.
If you require a new antisplasher / aerator this is our part SR63C/CB (available in Chrome).
Original codes known by 133.0068.762 SP1263 /1263R your original part may have Neoperl stamped around the edge.
How To remove the handle:
Loosen grub screw on the underside of handle using a 2mm allen key. Pull the handle horizontally away from the tap.
How to replace the spout o-rings:
Unscrew spout locking nut by hand then pull the spout vertically away from the body.
You can find the Calaggio tap instructions diagram below.
Watch our how to video for further general guidance on removing tap handle and replacing spout o'rings.