LAMONA GARDA (MK 2) TAP3562 TAP3564 KITCHEN TAP SPARES
Tap Magician fully compatible spares for the Howdens Lamona Garda TAP3562 TAP3564 kitchen Mixer Lever tap.
Our cartridge is compatible with ASCDV0003 / 4276R /3561R.
If your tap is leaking/dripping out of the spout then it is time to replace the cartridges.
The Lamona Garda tap cartridge has 28 splines. You will require our Anticlockwise open cartridge for the cold side, and clockwise open for the hot side, If you require both then you can select "Pair".
If your tap is leaking from the neck (where the spout joins the tap body) then the seals inside the spout need replacing. When you replace the new rubber seals they need greasing with a silicone grease. The original O'ring kit is known by 1425R SP1425
If you require a new lever handle then you can purchase our SH59R which is compatible with 3259R / SP3259.
Please note our handles do not have H or C on them.
Handles supplied with retaining screw. If you need a screw separately for the handle this is our SS81-S.
If you require a new antisplasher / aerator this is our part SR63C (Chrome or SR63CB (Brushed).
Original codes known by 133.0068.762 SP1263 / 1263R. Original part may have Neoperl stamped around the edge.
How to remove the TAP3564 TAP3562 lever handle and replace the cartridge?
Before replacing the cartridge you will need to turn the water off.
Step 1. Remove the handle retaining screw, by using a 2.5mm allen key.
Step 2. Pull the handle away from the tap body.
Step 3. Unscrew the tap shroud from the body. This will unscrew anticlockwise.
Step 4. Use a box spanner (ST03-S) to remove the recessed cartridge.
See the tap diagram below.
Lamona Garda Frequently asked questions
How to I remove the Lamona Garda tap handle?
Use 2mm allen key to undo handle. The grub screw is located on the underside of the handle. You can pull the lever forwards to access the screw at the back if you need more space.
How do I removed the recess Lamona Garda cartridge?
Our box spanner (STBOX-S) is available to enable easy removal and fitting of the cartridges which are recessed into the tap body.
How do I remove the spout and replace the o'rings inside the spout?
Use 2.5mm allen key to undo grub screw at the back holding the spout in place.
pull spout up and out of the tap body. You can watch our How to video above.
What size spanner do I need to remove the Garda tap handle?
You will need a 17mm or an adjustable spanner.